From Sequence control
From Sequence control
From Sequence control
From Sequence control
OFF2 S_src 2
p0845 [C]
From Sequence control
(1)
OFF3 S_src 2
From Sequence control
p0849 [C]
(1)
From Sequence control
OFF1
&
OFF2
1
From Sequence control
OFF3
Bit 9 = 1 --> Ready to exchange
Enable internal
missing or
fault with
this reaction
From sequence control
<1>
The drive is ready to accept data.
1
2
Internal control/status words
Status word, sequence control (r0899)
PROFIdrive-Bit
Bit No.
0
1 = Ready for switch on
[2610]
1
1 = Ready (DC link loaded, pulses inhibited)
[2610]
1 = Operation enabled (drive follows n_set)
2
[2610]
1 = Jog active
3
[2610]
4
1 = No coast down active (OFF2 inactive)
[2610]
5
1 = No Quick stop active (OFF3 inactive)
[2610]
6
1 = Switching on inhibited active
[2610]
1 = Drive ready
7
1 = Controller enable
8
[2610]
9
1 = Control requested
process data
10
Reserved
11
1 = Pulses enabled
[2610]
Reserved
12
Reserved
13
Reserved
14
15
Reserved
3
4
Status word sequence control (r0899)
<1>
5
6
fp_2503_97_01.vsd
13.03.2018
ZSW seq_ctrl
r0899
r0899
r0899.0
r0899.1
r0899.2
r0899.3
r0899.4
r0899.5
r0899.6
r0899.7
r0899.8
r0899.9
r0899.11
7
Function diagram
G120 CU230P-2
V4.7_10
8
- 2503 -