Siemens SINAMICS G120 Mode D'emploi page 627

Masquer les pouces Voir aussi pour SINAMICS G120:
Table des Matières

Publicité

OFF2 S_src 1
p0844 [C]
(2090.1)
p0840 [C]
&
OFF2 S_src 2
(2090.0)
p0845 [C]
(1)
OFF3 S_src 1
p0848 [C]
(2090.2)
p0852 [C]
&
OFF3 S_src 2
(2090.3)
p0849 [C]
p1140 [C]
(1)
(2090.4)
p1141 [C]
1st acknowledge
(2090.5)
p2103 [C]
(2090.7)
p1142 [C]
(2090.6)
2nd acknowledge
p2104 [C]
1
(722.2)
p1055 [C]
3rd acknowledge
p2105 [C]
(0)
p1056 [C]
Pulse generator
p0854 [C]
(2090.10)
p1113 [C]
(2090.11)
p1035 [C]
(2090.13)
p1036 [C]
(2090.14)
1
2
Internal control/status words
Control word 1 (r0054)
STW seq_ctrl
ON / OFF (OFF1)
r0898
[2501.7]
r0898
.0
r0898
[2501.7]
r0898.1
r0898
[2501.7]
r0898.2
Enable operation
r0898
[2501.7]
r0898.3
Enable RFG
r0898
[2501.7]
r0898.4
Continue RFG
r0898
[2501.7]
r0898.5
Setpoint enable
r0898
[2501.7]
r0898.6
r2138
[2546.7]
r2138.7
Jog bit 0
r0898
[2501.7]
(0)
r0898.8
Jog bit 1
r0898
[2501.7]
(0)
r0898.9
Master ctrl by PLC
r0898
[2501.7]
r0898.10
Setp inv
r1198
[2505.7]
r1198.11
Mop raise
r1198
[2505.7]
r1198.13
Mop lower
r1198
[2505.7]
r1198.14
r0836
[8560.7]
r0836.0
3
4
Bit No.
Control word 1 (r0054)
0 = OFF1, Shutdown via ramp, followed by pulse inhibit
0
1 = ON, operating condition (edge-controlled)
1 = OFF2: Electrical stop, pulse inhibit, motor coasts down
1
0 = Operating condition
1 = OFF3: Quick stop
2
0 = Operating condition
3
1 = Operation enable
4
1 = Ramp-function generator enable
5
1 = Continue ramp-function generator
6
1 = Speed setpoint enable
7
1 = Acknowledge fault
8
1 = Jog bit 0
9
1 = Jog bit 1
10
1 = Master ctrl by PLC
11
1 = Directions reversal (setpoint)
12
Reserved
13
1 = Motorized potentiometer raise
14
1 = Motorized potentiometer lower
15
1 = CDS bit 0
5
fp_2512_97_51.vsd
13.03.2018
STW 1
r0054
r0054
Sequence control
Setpoint channel
Sequence control
Sequence control
Setpoint channel
Sequence control
Setpoint channel
Setpoint channel
Setpoint channel
Sequence control
Sequence control
Setpoint channel
Sequence control
Setpoint channel
Bit 10 in STW1 must be set to ensure
that the drive accepts the process
data.
Setpoint channel
Setpoint channel
Setpoint channel
Sequence control
6
7
Function diagram
G120 CU230P-2
V4.7_10
8
- 2512 -

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cu230p-2Cu230p-2 hvacCu230p-2 btCu230p-2 dpCu230p-2 pnCu230p-2 can

Table des Matières