3.6 Gas adjustments
The injectors not supplied with the appliance should be requested from the
Service Centre.
If the cooking appliance is set up for a different type of gas than that available,
its injectors must be replaced, the minimum flow regulated and the rubber-
holder changed. In order to replace the injectors in the cooking hob, it is
necessary to carry out the following operations:
* remove the pan supports;
* remove the burners and burner caps
(Fig. A);
* take out the injector (Fig. B / Fig. C) and
replace it with one suitable for the new
type of gas (see "GENERAL INJECTORS
TABLE" on page 25, 25.);
* replace the gas label (on the rear of the
appliance) with the new one provided with
the injectors kit;
* refit all parts by following the
disassembly instructions in reverse order
and taking care to position the burner cap
correctly on the burner.
3.6.1 Mininum flow of valved cooking hob taps
* Switch on the burner and turn the
control knob towards the minimum
flow position ;
* remove the knob;
* using a screwdriver, adjust the
internal screw Z until the correct low
flame is obtained;
* refit the knob.
* Unscrew the adjustment screw Z to increase the flow, or tighten it to
reduce the flow.
* The adjustment is correct when the low flame measures approximately 3
or 4 mm.
* For butane/propane, the adjustment screw should be tightened all the way.
* When changing quickly from maximum to minimum flow and vice versa
23