3.3.1 Electric power cable section
According to the type of power supply, use a cable that conforms to the
following table.
A
Running at 400V3N~ (models connected according to DIAGRAM "A"):
use a pentapolar cable type H05RR-F (cable measuring 5 x 2.5 mm
Running at 230V3~ (models connected according to DIAGRAM "C" but
commutated by the installer according to DIAGRAM "B"): use a tetrapolar
cable type H05RR-F (cable measuring 4 x 4 mm
Running at 230V1N~ (models connected according to DIAGRAM "C"): up
to 2.9 kW use a tripolar cable type H05RR-F (cable measuring 3 x 1.5 mm
between 2.9 kW and 5.4 kW use a tripolar cable type H05RR-F (cable
measuring 3 x 2.5 mm
type H05RR-F (cable measuring 3 x 4 mm
type H05RR-F (cable measuring 3 x 6 mm
The end to be connected to the appliance must have the earth wire (yellow-
green) at least 20 mm longer.