13. Simple Network Management Protocol (SNMP) Management

13.2.4 Alarm Group

To set up an alarm group for specified data traffic events to trigger at upper and lower thresholds, configure the following items
(Figure 13.20):
1. Index – Set the alarm list index number from 1~65535.
2. Statistical Event – Set the type of event to trigger an alarm. The event types are: DropEvents, Octets, Pkts, BroadcastPkts, MulticastPkts,
CRCAlignErrors, UndersizePkts, OversizePkts, Fragments, Jabbers, Collisions, Pkts64Octets, Pkts65to127Octets, Pkts128to255Octets,
Pkts256to511Octets, Pkts512to1023Octets and Pkts1024to1518Octets.
3. Statistical Group Index – Enter the corresponding statistic Group Index number to monitor the port number.
4. Sampling Time Interval – Enter the sample time interval between 5~65535 seconds .
5. Sample Type – Choose the sample type of either Absolute or Delta.
6. Owner – Enter the owner's name. Supports 1-30 characters.
7. Upper Alarm Threshold Limit – Enter the amount of data traffic to set the upper threshold limit from 0-2147483647.
8. Upper Alarm Threshold Limit Events – Chose the Event Group that you want to trigger when the upper alarm threshold is reached.
9. Lower Alarm Threshold Limit – Enter the amount of data traffic to set the lower threshold limit from 0-2147483647.
10. Lower Alarm Threshold Limit Events – Chose the Event Group that you want to trigger when the lower alarm threshold is reached.
11. Click "Save" to save configuration. Click "Exit" to discard settings.
Figure 13.20: New Alarm Group