Section of the C and D cables
Model
BUy-1020
BUy-1050
BUy-1065-6 ... BUy-1085
The cable must be twisted, maximum length: 2 meters.
For UL Compliance use the following cable: AWG 4 600V UL62-ST.
n
!
ote
3.2.6. Dip-switch Description
The following table lists the switches on the regulation card, removing the front cover of
the braking unit.
n
!
The BUy1065-6 and BUy-1075-5 models are not provided with the voltage
ote
selection switch.
Denomination
BUy-1020
BUy-1050
Mains
BUy-1085
Voltage
Buy-1065-6
Buy-1075-5
S2
S3
S4
Remove power, and insure DC link is discharged before opening cover and
W
!
arning
changing settings.
Maximum permissible Cable Cross-Section
flexible [mm]
Mains Voltage
[Vac]
230
380
400
415
440
460
480
690
575
MASTER = Selection of braking unit function as Master
SLAVE = Selection of braking unit as Slave (S4=ON)
Button Reset of alarm condition
Enabling of the function for quick discharge of the DC link = ON
—————— Braking Unit ——————
multi-core [mm]
4
10
25
Function
Braking threshold
Turn ON
[Vdc]
402
646
678
702
743
753
775
1150
965
AWG
12
8
4
tbu0045g
Turn OFF
[Vdc]
382
626
658
682
723
733
755
945
945
tbu0050g