7. SETTING PROCEDURE OF THE SEWING DATA
The standard patterns of pattern Nos. 90 to 99 can change the sewing speed and the thread tension,
however, cannot change the sewing shape. When changing the shape , it is necessary to copy the
shape to another pattern No. [See item (20) Copy destination No. on page 38.]
!8
!9
@0
8
2
7
!0
!3
!2
When changing the pattern No. without pressing [READY
are not stored in memory.
6) When the memory switch No. 20 is set to "1", change of data setting in the above step 4) can be prohibited.
(See the item of the memory switch on page 68.)
The data No. is stated in 2-digit LED @0 and the example of the set value is stated in 4-digit LED @1 as
shown below. The setting range is stated in the respective sentences.
@1
!7
!6
6
5
!1
9
3
4
1
!4
!5
1) Confirm that sewing LED !9 has gone out.
When it lights up, press [READY
make it go out.
2) Display the pattern No. you desire to change the
data .
3) Press the respective setting keys of the parts
desired to be changed and display the data.
[SHAPE
] key
1
[LENGTH
] key
2
[CB
] key
3
[CA
] key
4
[STITCHES
] key
5
[STITCHES
] key
6
[SPACE
] key
7
[SPACE
] key
8
[LENGTH
] key
9
!0 [STITCHES
] key
!1 [OFFSET
] key
!2 [MAX
] key
!3 [EYELET
] key
!4 [FUNCTION F1
[FUNCTION F2
!5
4) Press [RIGHT
] key !6 or [RIGHT
set the respective data.
5) Press [READY
] key !8 to light up sewing LED
!9 and the data are stored in memory.
] key or turning OFF the power, the data
] key !8 to
] key
] key
] key !7 to
21