CALYS 50 / 75 / 100
B.2.7
Pulse counting
Display the MEASUREMENT CONFIGURATION dialogue box:
Select the Counting measurement function, then the "type of input" Signal or Hard Contact using the function
and navigation keys.
Enter the counting time using the alphanumeric keys.
Confirm with ENTER.
Connection is made between the Hz and COM terminals.
The input signals are converted into a logic signal as in the case of signal frequency or hard contact measurement.
If you enter a zero counting time, the counting lasts indefinitely.
To initiate counting, confirm with the Start function key ("F3").
To stop counting without resetting the counter value, confirm with the Stop key.
To reset the counter to zero, press the Clr key (F4)
The counting period is displayed in the left part of the IN window. This period is reset whenever counting is stopped.
114 / 164
NTA47227-300A8