Characteristic
Programming & measurement tempCo/°C 2
Voltage:
Current:
Output ripple & noise (20 Hz to 20 MHz)
CC rms:
Common mode current
rms:
peak-to-peak:
Overvoltage protection
Maximum setting:
Accuracy:
Response time: 3
Voltage up/down programming, comp 0 4
Rise/fall time 10% to 90% of step:
Settling time to 0.1% of step:
Voltage up/down programming, comp 1 4
Rise/fall time 10% to 90% of step:
Settling time to 0.1% of step:
Voltage up/down programming, comp 2 4
Rise/fall time 10% to 90% of step:
Settling time to 0.1% of step:
Current up/down programming 5
Rise/fall time 10% to 90% of step:
Settling time to 1% of step:
Power up/down programming 6
Rise/fall time 10% to 90% of step:
Settling time to 1% of step:
Output on delay time 7
Voltage priority - high impedance:
Voltage priority - low impedance:
Current priority:
Maximum load inductance: 8
Line regulation
Voltage and current:
Typical leakage current
Output disabled, or unplugged from mains
Bleed resistor
+/- Terminals to chassis ground:
1 200/208 Vac input reduces the current and power rating 50%; 200/208 Vac input is only available with firmware rev B.06.03.1003 and up
2 Applies for ambient temperatures above 30°C or below 20°C.
3 From occurrence of over-voltage to start of shutdown
4 With no load and a step change from 0.1% to 100% of voltage rating; bandwidth frequency = 100 kHz
5 With ac short and a step >10% of output voltage rating; bandwidth frequency = 100 kHz
6 With load voltage = 50% of voltage rating and a step change from 0 to 100% of voltage rating; load ESR= 0 Ω; load ESL = 0 µH
Bandwidth parameters are set as follows: Vmin = 25% of voltage rating; Lsense = default; Frequency = 100 kHz
7 Time from when the Output On command is received to the initiation of turning the output on
8
Unit is susceptible to internal damage if Maximum Load Inductance limits are exceeded at the rated current
9 Due to the pre-regulation circuits in the unit, the line regulation is not measurable
Keysight RP7970 & RP7980 Series Operating and Service Guide
RP7971A
0.002%+4 mV
0.002%+7 mV
0.005%+480µA
0.005%+240µA
60 mA
3.5 mA
45 mA
600 V
0.02% + 50 mV
0.04% + 75 mV
< 30 µs
0.2 ms
1 ms
0.5 ms
2.5 ms
33 ms
110 ms
100 µs
200 µs
0.5 ms
1.5 ms
8.1 ms
8.1 ms
7.1 ms
45 µH
See Note 9
0.75 mA
68 MΩ
1 Quick Reference
RP7972A
RP7973A
0.002%+14 mV
0.005%+120µA
30 mA
2.5 mA
30 mA
1200 V
0.04% + 150 mV
< 30 µs
0.2 ms
1 ms
0.5 ms
2.5 ms
33 ms
110 ms
100 µs
200 µs
0.5 ms
1.5 ms
8.1 ms
8.1 ms
7.1 ms
185 µH
See Note 9
See Note 9
0.75 mA
0.75 mA
68 MΩ
15 mA
2.5 mA
30 mA
2400 V
< 30 µs
0.2 ms
1 ms
0.5 ms
2.5 ms
33 ms
110 ms
100 µs
200 µs
0.5 ms
1.5 ms
8.1 ms
8.1 ms
7.1 ms
740 µH
68 MΩ
39