Keysight RP7971A Guide D'utilisation Et De Maintenance page 32

Système d'alimentations régénératrices

Publicité

1 Quick Reference
                  :RANGe 0 | 1
            :CURve
                  :IMP <value>
                  :ISC <value>
                  :SHAPe SPACe|TERRestrial
                  :VMP <value>
                  :VOC <value>
            :MODE FIXed|CURVe|TABLe
            :SCALe
                 :CURRent <value>
                 :VOLTage <value>
            :TABLe
                 :ACTivate 1|2
                 :SELect 1|2
                 :UPDate 1|2
            :TABLe[1|2]
                  :CURRent
[:AMPLitude] <value>{,<value>}
                        :POINts?
                  :VOLTage
[:AMPLitude] <value>{,<value>}
                        :POINts?
[SOURce:]
STEP
            :TOUTput 0|OFF|1|ON
[SOURce:]
VOLTage
[:LEVel]
[:IMMediate]
[:AMPLitude] <value>
                  :TRIGgered
[:AMPLitude] <value>
            :BWIDth
                  :LEVel 0 | 1 | 2, <value>
                  :RANGe 0 | 1 | 2
            :LIMit
[:POSitive]
[:IMMediate]
[:AMPLitude] <value>
                  :LOW <value>
                        :STATe 0|OFF|1|ON
            :MODE FIXed|STEP|LIST|ARB
32
Sets the SAS compensation.
Sets the current at the maximum power point of the curve.
Sets the short-circuit current.
Sets the curve shape.
Sets the voltage at the maximum power point of the curve.
Sets the open-circuit voltage.
Sets the operating mode of the instrument.
Sets a scale factor for the curve in both SAS and Table modes.
Sets a scale factor for the curve in both SAS and Table modes.
Loads and runs the table created using the MEMory commands.
Runs one of two tables that have been loaded.
Updates a table.
Programs a list of current points in Table mode.
Returns the number of current points in the current table.
Programs a list of voltage points in Table mode.
Returns the number of current points in the voltage table.
Specifies whether a trigger out is generated when a transient step occurs.
Sets the output voltage when in voltage priority mode.
Sets the triggered output voltage.
Sets the bandwidth limit of voltage programming.
Sets the voltage compensation range.
Sets the voltage limit when in current and power priority mode.
Sets the low-voltage limit.
Enables or disables the low-voltage limit.
Sets the transient mode.
Keysight RP7970 & RP7980 Series Operating and Service Guide