Parameter
0 | 1 | 2, *RST 0
Sets the voltage bandwidth to comp 1: VOLT:BWID:RANG 1
[SOURce:]VOLTage:LIMit[:POSitive][:IMMediate][:AMPLitude] <value>|MIN|MAX
[SOURce:]VOLTage:LIMit[:POSitive][:IMMediate][:AMPLitude]? [MIN|MAX]
Sets the voltage limit when in current or power priority mode.  Units are in volts.
Parameter
0.1% to 102% of rating, *RST 1% of rating
Sets the voltage limit to 20 V: VOLT:LIM 20
[SOURce:]VOLTage:LIMit:LOW <value>|MIN|MAX
[SOURce:]VOLTage:LIMit:LOW? [MIN|MAX]
Sets the low voltage limit when in current or power priority mode. This prevents the voltage from
dropping below the low voltage limit when discharging a battery. When the voltage drops to the
specified low limit value, the output transitions from current priority to negative voltage limit and the
discharging stops. This sets the LIM- bit in the Questionable Status Register.
Parameter
0 to 102% of rating, *RST 0
Sets the low voltage limit to 2 V: VOLT:LIM:LOW 2
This command is coupled to the VOLTage:LIMit command. The voltage limit must always be pro-
l
grammed to a higher value than low voltage limit.
The low voltage limit also prevents the output from turning on when the output voltage is below
l
the programmed low voltage limit. Refer to VOLTage:PROTection:LOW:DELay.
The low voltage limit is disabled in power priority mode. To use this feature you must program a
l
low voltage limit after power priority mode is enabled.
[SOURce:]VOLTage:LIMit:LOW:STATe 0|OFF|1|ON
[SOURce:]VOLTage:LIMit:LOW:STATe?
Enables or disables the low-voltage limit.
Parameter
0|OFF|1|ON, *RST OFF
Enable the low voltage limit state: VOLT:LIM:LOW:STAT ON
Keysight RP7970 & RP7980 Series Operating and Service Guide
5 SCPI Programming Reference
Typical Return
0, 1, or 2
Typical Return
<voltage limit>
Typical Return
<low voltage limit>
Typical Return
0 or 1