FUNCtion Command
[SOURce:]FUNCtion CURRent|POWer|VOLTage
[SOURce:]FUNCtion?
Sets the output regulation - voltage, power, or current priority. In voltage priority mode, the output is
controlled by a constant voltage feedback loop, which maintains the output voltage at its
programmed setting. In current priority mode, the output is controlled by a constant current feedback
loop, which maintains the output current at its positive or negative programmed setting. In power
priority mode, the output is controlled by a constant power feedback loop, which maintains the output
power at its positive or negative programmed setting.
Refer to
Priority Mode Tutorial
Parameter
CURRent|POWer|VOLTage, *RST VOLTage
Sets the output regulation to current priority: FUNC CURR
Keysight RP7970 & RP7980 Series Operating and Service Guide
for more information.
Typical Return
CURR, POW, or VOLT