ARB Subsystem
ARB commands program the constant-dwell arbitrary waveforms. Constant-dwell waveforms can
have up to 65,535 points assigned to them, with the same dwell time for each point.
[SOURce:]ARB:COUNt <value>|MIN|MAX|INFinity
[SOURce:]ARB:COUNt? [MIN|MAX]
Specifies the number of times the Arb repeats. Use the INFinity parameter to repeat the Arb
continuously.
Parameter
1 – 256, *RST 1
Programs a repeat count of 10: ARB:COUN 10
[SOURce:]ARB:CURRent:CDWell[:LEVel] <value>{,<value>}|<Block>
[SOURce:]ARB:CURRent:CDWell[:LEVel]?
[SOURce:]ARB:POWer:CDWell[:LEVel] <value>{,<value>}|<Block>
[SOURce:]ARB:POWer:CDWell[:LEVel]?
[SOURce:]ARB:VOLTage:CDWell[:LEVel] <value>{,<value>}|<Block>
[SOURce:]ARB:VOLTage:CDWell[:LEVel]?
Specifies the level of each point in the Arb.  Values are specified in either amperes, watts, or volts.  The
minimum and maximum values depend on the ratings of the unit.
Current, power, and voltage Arbs share settings, so setting this parameter for a current Arb also
changes the voltage Arb and power Arb to the default values and vice versa.For better performance,
the list can be sent as single precision floating point values in definite length arbitrary block format
instead of an ASCII list. The response format is dependent on the return format ASCII or REAL.
Parameter
-102% to 102% of current or power rating or 0 to
102% of voltage rating
*RST is 1 point with a value of MIN
Programs a constant dwell Arb of 5 voltage points:ARB:VOLT:CDW 5,4,3,2,1
Keysight RP7970 & RP7980 Series Operating and Service Guide
5 SCPI Programming Reference
Typical Return
<count>
Typical Return
<value> [,<value>]
or
<Block>