Front Panel Menu Reference
Select Transient\Mode.
In voltage priority mode select Voltage mode. In
current priority mode select Current mode. In power
priority mode, select Power mode. In the dropdown
list, select List. Then press Select.
Program the list levels
Example 1 If you are programming a voltage pulse or pulse train, set the amplitude of the pulse. For
example, to generate a pulse with an amplitude of 15 V, program the amplitude for the pulse (step 0),
and the amplitude for the off time (step 1).
Front Panel Menu Reference
Select Transient\List\Config.
Select List Step 0 (the pulse) and enter a voltage value of
15. Press Select.
Select List Step 1 (the off time) and enter a voltage value of
0. Press Select. Use the numeric up/down arrows to select
the next step.
Example 2 If you are programming a voltage list, specify the amplitudes for the list. The order in which
the values are entered determines the order in which the values will be output. To generate the voltage
list shown in the figure, a list may include the following values: 9, 0, 6, 0, 3, 0:
Front Panel Menu Reference
Select Transient\List\Config.
Select the List Step number and enter a voltage value.
Press Select. Repeat this for each step.
Use the numeric up/down arrows to select the next step.
Keysight RP7970 & RP7980 Series Operating and Service Guide
4 Using the Regenerative Power System
SCPI Command
To enable the transient function, use:
VOLT:MODE LIST
or
CURR:MODE LIST
or
POW:MODE LIST
SCPI Command
To program the amplitude for step 0 (the pulse)
and step 1 (the off time):
LIST:VOLT 15,0
SCPI Command
To program a voltage list of 5 steps:
LIST:VOLT 9,0,6,0,3,0