Keysight RP7971A Guide D'utilisation Et De Maintenance page 268

Système d'alimentations régénératrices

Publicité

5 SCPI Programming Reference
105 Unexpected output current
The measured output current is outside the acceptable range.
106 Zero measurement out of range error
The "zero" measurement value is outside the acceptable range.
107 Programming cal constants out of range
The programmed calibration constant is outside the acceptable range.
108 Measurement cal constants out of range
The measurement calibration constant is outside the acceptable range.
109 Over voltage cal constants out of range
The over voltage calibration constant is outside the acceptable range.
110 Wrong V+I
The instrument was unable to set the correct voltage or current value.
114 Wrong status
An incorrect status function has been reported.
116 Locked out by internal switch setting
This function has been locked out by an internal switch.
117 Calibration error
A calibration error has occurred. Do not save calibration constants. Try re-calibrating the unit.
200 Hardware error channel <1>
A hardware error has occurred on the output.
201 Invalid configuration
An invalid parallel configuration is not allowed.
202 Selftest Fail
A selftest failure has occurred.
203 Compatibility function not implemented
The requested compatibility function is not available.
204 NVRAM checksum error
A checksum error has occurred in the instrument's nonvolatile random access memory.
205 NVRAM full
The nonvolatile random access memory of the instrument is full.
268
Keysight RP7970 & RP7980 Series Operating and Service Guide