BWT Electrolyseur ECO MX Nano Notice De Montage, Mise En Service, Exploitation Et Maintenance page 57

Système de production de chlore sur site par électrolyse de sel

Publicité

Les langues disponibles

Les langues disponibles

- Locate the new hose. Ensure that the tube
is well lubricated with silicone grease
- Pull the rotor backwards slightly and insert
the tube between the inside of the casing
and the rotor
- Replace the transparent panel
- Reconnect the hoses
- Wipe away all chemical solution residue
from the system
- Complete the dedicated service sheet for
this procedure.
- Return the system to operation by following
the commissioning procedure.
10.7 sHuttING DoWN tHE uNIt
10.7.1 short-term shutdown (up to 2 months)
Access the "restart" menu
To reactivate commissioning, in the service
menu, hold down the "Recommission"
("Remise en service") button for 3 seconds.
- Completely purge the production reactor
- From the commissioning menu, set the softened water injection pump to run for 20 minutes to rinse
the chlorine or salt solution out of the electrolysis circuit.
- After 20 minutes, stop the injection pump.
- Close the upstream water supply.
- Leave the system powered up.
Returning the unit to operation:
- Purge the reactor of all contents.
- Reactivate the system using the recommissioning procedure described in the "Recommissioning" chapter.
10.7.2 Shutting down for longer periods (over 2 months)
Procedure:
-To reactivate commissioning, go to the service menu and hold down the "Recommission" ("Remise en
service") button for 3 seconds.
- Completely purge the production reactor.
- Close the valve.
- From the "Commissioning" ("Mise en service") menu, set the softened water injection pump to run
for 20 minutes to rinse the chlorine or salt solution out of the electrolysis circuit.
- Disconnect the system power.
- Close the upstream water supply.
- Completely purge the production reactor.
- Recommissioning the system will require carrying out the pre-startup and commissioning checks.
- Change the Santoprene or silicone hoses on the injection pumps.
Insert
Technical manual ECO MX NANO electrolyser - code EN_P0011183 - Rev 7 - 19/04/2019
Rotor assembly
Pump lid
Pump tube
Insert
Axis
57