2. Eco MX NaNo sPEcIFIcatIoNs
2.1 ProDuctIoN sPEcIFIcatIoNs
FAC capacity
FAC capacity
FAC concentration
Production flow rate
2.2 coNsuMPtIoN
Water consumption
Salt consumption, approx.
Electrical consumption, approx.
2.3 oPEratING coNDItIoNs
Inlet water temperature *
Inlet water pressure
Water quality
Water hardness
Ambient temperature
Salt
the maximum water temperature at the inlet must never exceed 30°c and an ambient temperature of
35°c maximum. the device is installed in a dust-free environment.
Depending on the power demanded on the electrolysis cell, the temperature of the water can increase by about
9 to 12°C with respect to the inlet temperature. The alarm set point for the water temperature is outlet set at
40°C (max 49°C) and is measured by the temperature sensor included in the ECO MX NANO electrolyser system.
2.4 ElEctrIcal sPEcIFIcatIoNs
Supply voltage
Power rating
Rated absorbed AC current
Power cable
Protection
1. INtroDuctIoN
uNIts
g/h
kg/day
g/l
l/h
uNIts
l/h
kg/kg Cl2
kWh/ kg Cl2
uNIts
Bar
* IMPortaNt :
uNIts
watt
Technical manual ECO MX NANO electrolyser - code EN_P0011183 - Rev 7 - 19/04/2019
Eco MX NaNo
Eco MX NaNo
Eco MX NaNo
°C
similar to that of drinking water
°F
°C
EN 14805 standard (type 1 dry salt)
Article 95 Regulation 528/2012
Eco MX NaNo
V
A
male plug, 2m length, 3G1.5 cross-
max. 30mA differential
45
1
4 +/- 1
11 +/- 15%
11 +/- 15%
4
6
+5 to +25
1 to 3
< 0.1°F
+5 to +25
supplier
1x230
420
2
section
37