8.3 rEcoMMIssIoNING
To activate commissioning, go to the service
menu by pressing the "SERVICE" button then
hold down the "RECOMMISSION" ("Remise
en service") button for 3 seconds.
When this becomes red, the commissioning
function is reactivated and will be displayed
in green in the main menu.
Press the "HOME" button to go back to
the main menu.
Apply the procedure as shown in chapter 8.1
"COMMISSIONING" to return the system to
operation.
8.4 IMPortaNt NotEs
Hardness
Regularly check the absence of hardness in the softened water.
Ensure that the level of salt in the water softener reservoir is maintained constant.
Chlorinated solution production must not operate during regeneration cycles.
Hydrogen
To guarantee safe operation, the hydrogen by-product of the electrolysis process must be vented.
A ventilation duct to an outside vent must be fitted to the system and used only for this purpose.
Pay close attention to the "OXIDANT RESERVOIR AND HYDROGEN VENTS" CHAPTER.
Hydraulic (Breaks fittings)
The connections used on the hydraulic side are of the union type and must be manually tightened without
tools in order to avoid breakage.
Technical manual ECO MX NANO electrolyser - code EN_P0011183 - Rev 7 - 19/04/2019