● Reserve wire:
Reserve wire should be installed at
several points to make it easier to
subsequently change the routing of the
perimeter wire. (
12.14)
Coiled up residual pieces of
perimeter wire can cause
malfunctions and must be removed.
12.2 Making a sketch of the
mowing area
During installation of the robotic
mower and the docking station, it is
recommendable to make a sketch of the
mowing area. A page has been provided at
the start of this Instruction Manual for this
purpose.
The sketch should be modified in the event
of subsequent changes.
Content of the sketch:
– Contour of the mowing area including
important obstacles, borders and any
no-go areas which the robotic mower
must not mow. (
27.)
– Position of the docking station (
– Position of perimeter wire
After a short while, the perimeter wire is
overgrown and is no longer visible.
Make a note of the routing of the wire
around obstacles in particular. (
– Position of the wire connectors
After a short while, the wire connectors
used are no longer visible. Their
position should be noted in order to
replace them as required. (
136
12.3 Routing the perimeter wire
Only use original fixing pins and
original perimeter wire. Installation
kits with the necessary installation
material are available as an
accessory from the VIKING
specialist dealer. (
The routing direction (clockwise or
anti-clockwise) is freely selectable
according to requirements.
1
Never pull out fixing pins using the
perimeter wire – always use a
suitable tool (e.g universal pliers).
Make a sketch of the perimeter wire
routing. (
● Install the docking station. (
● Route the perimeter wire around the
mowing area and any obstacles
beginning at the docking station
(
12.7) and fasten it to the ground
using fixing pins. Check the clearances
using the iRuler. (
Follow the instructions in the "Initial
installation" section. (
9.9)
● Connect the perimeter wire. (
12.4 Connecting the perimeter wire
9.10)
● Disconnect the mains plug
and then remove the docking
station cover.
● Insert the perimeter wire into the cable
guides of the floor plate, guide it
12.15)
through the socket, strip the ends and
connect to the docking station.
Follow the instructions in the "Initial
installation" section. (
18.)
12.2)
9.9)
12.5)
9.10)
9.11)
9.11)
● Install the docking station
cover and then connect the
mains plug.
● Check the wire signal. (
● Check docking. (
15.7)
If necessary, correct the position of the
perimeter wire in the area of the
docking station.
12.5 Wire clearances – use iRuler
The perimeter wire (1) can be routed
without clearance along obstacles that
can be travelled on such as patios and
paths. The robotic mower then travels with
one rear wheel outside the mowing area.
Maximum height difference between lawn
area and obstacle: 2 cm
Take care not to damage the
perimeter wire when tending to the
lawn edge. If necessary, install the
perimeter wire at a slight distance
(2 - 3 cm) from the lawn edge.
0478 131 9936 B - EN