Then press the OK button on the
control panel.
If the battery is discharged, a
plug symbol appears instead
of the battery symbol at the
top right corner of the display after
docking and the battery is charged
while the perimeter wire is being
routed. (
15.8)
9.10 Routing the perimeter wire
Please read and observe the entire
"Perimeter wire" section before
performing wire routing. (
In particular, plan the routing,
observe the wire clearances and
install no-go areas, reserve wire,
linking sections, secondary
areas and corridors during wire
routing.
For mowing areas < 40 m² and only
when the red LED on the docking
station signals SOS, the accessory
AKM 100 must be installed
together with the perimeter wire.
0478 131 9936 B - EN
Route the perimeter wire starting at the
docking station. A distinction must be
made between an internal docking
station and an external docking station
here.
Starting routing with an internal
docking station:
12.)
Fasten the perimeter wire (1) to the ground
on the left or right as appropriate, next to
the floor plate, directly next to a wire outlet,
using a fixing pin (2).
Provide a free wire end (1) with a length of
approx. 1.5 m.
Route the perimeter wire (2) in front of and
behind the docking station (1) for 0.6 m in
a straight line and at right angles to the
floor plate. Then follow the edge of the
mowing area with the perimeter wire.
If offset drive home (passage) is
used, the perimeter wire must be
routed at least 1.5 m in front of and
behind the docking station in a
straight line and at right angles to
the floor plate. (
11.14)
113