– Live underground cables, reinforced
concrete or disruptive metals in the
ground under the docking station
– Maximum length of the perimeter wire
exceeded (
12.1)
Remedy:
– Repeat linking without other corrective
action
– Dock the robotic mower (
– Connect the perimeter wire ends
correctly (
9.11)
– Check the docking station mains
connection, roll out the power cable in
the vicinity of the docking station, do not
set down coiled
– Check the seating of the wire ends in
the terminal block, shorten excessively
long wire ends and twist the wire ends
together (
9.11)
– Install the accessory (AKM 100)
– Check the LED indicator on the docking
station (
13.1)
– Repair the wire break
– Switch off mobile phones or nearby
docking stations
– Change position of the docking station
or remove interference sources under
the docking station
– Use perimeter wire with larger cross
section (special accessory)
Following the appropriate corrective
action, repeat linkage by pressing
the OK button.
Contact your specialist dealer if the
measures described above do not
result in a correct wire signal.
120
9.13 Checking installation
15.7)
Start the test run by pressing the OK
button – this does not activate the
mowing blade.
The robotic mower alternately
follows the edge of the mowing
area in both directions during
running operation after initial
installation. Edge following should
therefore also be checked in both
directions during initial installation.
MI 632 C, MI 632 PC:
The test run is used to define the
home area of the robotic mower.
(
14.5)
If the robotic mower is not receiving
a GPS signal before the test run
starts, the text "Waiting for GPS"
will appear on the display. The
robotic mower will start the test run
after a few minutes despite no GPS
signal being received.
As the robotic mower follows the edge,
walk behind it and ensure:
– that the robotic mower follows the edge
of the mowing area as planned,
– that the clearances to obstacles and the
borders of the mowing area are correct,
– that docking in and out takes place
correctly.
The distance covered is shown on the
display – this metric specification is
required for setting starting points at the
edge of the mowing area. (
● Read off the displayed value at the
required location and write it down.
Manually set starting points after initial
installation.
The following of edges is automatically
interrupted by obstacles, during operation
on excessively steep slopes or by pressing
the STOP button.
● If the test run has been interrupted
automatically, correct the position of the
perimeter wire and remove any
obstacles.
0478 131 9936 B - EN
11.14)