6. PROBLEMS / CAUSES / SOLUTIONS
ATTENTION:
All repairs must be carried out exclusively by
a specialised technician, with the stove
completely cold and the stove unplugged.
PROBLEM
Pellets not being fed
into
the
combustion
chamber.
The fire goes out or the
stove
stops
automatically.
The stove runs for a
few minutes and then
goes out.
Pellets
build
up
grate, door glass gets
dirty and flame is weak.
Problems/Causes/Solutions
INSTALLATION AND USE MANUAL
POSSIBLE CAUSES
 Pellet hopper empty.
 Feeder screw blocked by sawdust.
 Feed motor defective.
 Defective electronic board.
 Pellet hopper empty.
 Pellets not being fed in.
 Intervention of pellet temperature sensor.
 Door not closed properly or gaskets
worn.
 Unsuitable pellets.
 Low pellet feed rate.
 Combustion chamber dirty.
 Smoke outlet obstructed.
 Combustion blower failed.
 Lighting cycle not completed.
 Temporary failure of electricity supply.
 Smoke duct obstructed.
 Temperature sensors defective or broken.
 Igniter failure.
in
 Insufficient combustion air.
 Pellets damp or unsuitable.
 Combustion blower broken.
PELLET STOVES
 Refill pellet hopper.
 Empty the hopper and manually free the
auger of sawdust.
 Replace feed motor.
 Replace electronic board.
 Refill pellet hopper.
 See previous problem..
 Let the stove cool down completely, reset
the
relight stove; if problem persists, and
contact technical assistance.
 Close the door or replace the gaskets
with original spare parts.
 Change to a type of pellet recommended
by the manufacturer.
 Have the fuel feed rate checked by
technical service.
 Clean the combustion chamber, following
instructions in the manual.
 Clean the vent system.
 Check the motor and replace if
necessary.
 Re-run lighting cycle.
 See previous instruction.
 Clean vent system.
 Check
necessary.
 Check
necessary.
 Check that the room air intake is present
and free.
 Check that the combustion air filter on the
air inlet is not obstructed.
 Clean the grate and check that all the
airways are clear.
 Carry out a general cleaning of the
combustion
system.
 Check the state of the door gaskets.
 Change the type of pellet.
 Check the motor and replace if
necessary.
Technical service - Rights reserved MCZ Group S.p.A. - Reproduction prohibited