4.15. Exiting alarm condition
If an error code or alarm interrupts the operation of the stove you can
re-set the normal operation of the stove by pressing the on/off key for
a long time. After a short verification phase if the cause that caused the
alarm does not persist, the stove leaves the alarm status and it may
restart.
Shutdown of the stove
4.15.1.
The following things can cause stove shutdown:
Overheating of the stove body ("A03")
Overheating of the exhaust ("A04")
During the function of the stove, an uncontrolled air intake
occurred in the combustion chamber or an obstruction in the flue
pipe. ("A05")
WHAT TO DO:
When the stove is cold: if the message "A03" appears: The structure is
too hot because the product has been operating for too long at
maximum power, or it is poorly ventilated, or the air fans are faulty
When the stove is sufficiently cold, press button B of the control panel
or OFF on the remote control to cancel the alarm A03. Once the alarm
is cancelled it is possible to relight the stove normally.
If the alarm "A04" appears the stove shutdown in automatic, leave it
to cool down for a few minutes and then re-light. Cancel the alarm and
re-light.
If the alarm "A05" appears: it is caused by prolonged opening of the
fire door or by substantial air infiltration (e.g. combustion blower
inspection plug missing). If not caused by these factors control the
smoke outlet protection against the strong wind and if necessary clean
the smoke duct and the flue pipe.
Only after the cause of the blockage has been permanently
eliminated can a fresh attempt to relight the stove be made.