Wall outlet (method #1)
3.4.2.1.
This method provides excellent venting for normal operation and
allows the stove to be installed closest to the wall. Two and a
half inches from the wall is safe; however, three inches allows
better access to remove the rear panel. The vertical portion of
the vent should be three to five feet high. This vertical section
will provide natural draft in the event of a power failure. Note: do
not place joints within wall pass-throughs.
Wall outlet (method #2)
3.4.2.2.
This method also provides excellent venting for normal operation
but requires the stove to be in-stalled farther from the wall. The
vertical portion of the vent should be three to five feet high and
at least three inches from a combustible wall. This vertical
section will provide natural draft in the event of a power failure.
Note: do not place joints within wall pass-throughs.
Installation and fitting
PELLET STOVES
INSTALLATION AND USE MANUAL