Room sensor
4.7.3.1.
The room sensor (B) is placed behind the stove near the switch. You
are advised to extract the room sensor so that it extends out as in
figure (about 2 ½"). This way it is not thrown off by the heat of the
stove. It is advisable to do this during installation, since before
extracting the probe (B) it is necessary to take off the clamp (C) that
keeps it connected; operation possible by working inside the stove thus
without the sides. To extract the probe (B) it is necessary to unscrew
the protection cap (A) and slowly pull the probe (B). After extracting
the probe (B) sufficiently, close the protection cap (A) again.
ATTENTION! Once the clamp that binds the probe
wire is taken off, avoid it coming into contact with the
hot parts of the stove.
External thermostat connection
4.7.3.2.
It is possible to connect the stove to an external thermostat. To make
this connection it is necessary to acquire the interface D (optional) that
is connected to the motherboard (E) of the stove on the manifold (F) as
indicated in the diagram below and in pag.53 par.7.
A
B
F
Operation
PELLET STOVES
INSTALLATION AND USE MANUAL
Fig.9
-
Interface
environment thermostat
D
E
Fig.7 - Room temperature sensor
Fig. 8 - Motherboard (internal
for
the
stove)
Technical service - Rights reserved MCZ Group S.p.A. - Reproduction prohibited
Chapter 4
page
A = PROTECTION CAP
B = PROBE (FLUSH)
C = CLAMP
D
=
INTERFACE
EXTERNAL THERMOSTAT
E = MOTHERBOARD
F
=
CONNECTOR
INTERFACE CONNECTION
G
=
HOLES
FOR
OUTLET
41
B
C
FOR
FOR
CABLE