FIRST LIGHTING
4.6.
4.6.1. ON/OFF from the control panel or remote
control (if purchased)
To switch the stove on and off, press the key B for 2 seconds on the
control panel or the A button on the remote control (if purchased).
After a start-up phase that lasts about 15 minutes, the stove
will come up to full operating power.
After the stove is shut down by pressing button B on the remote
control or the B button on the control panel, the cooling-off procedure
begins. This includes the interruption of fuel loading, the cleaning of the
grate and the continuation of ventilation until the stove is sufficiently
cold. This phase may last from 20 to 40 minutes depending on how
long the stove was lit for and where it is located.
4.6.2. Note: first ignition
The first attempt at ignition may not be successful,
since the auger is empty and it is not always able to
fill the grate with required amount of pellets in time
to insure normal ignition
CANCEL
THE
CONTROL PANEL (see paragraph 4.14)., REMOVE
PELLETS IN THE GRATE AND REPEAT LIGHTING
After repeated attempts at lighting, if there is no flame even though
pellets are flowing normally, check that the grate is correctly
positioned. It must be placed where it sits perfectly to its housing
and free of any ash or carbon build up. If no abnormalities are
found, it means that there may be a problem with the stove
components or that installation may not have been carried out
correctly.
REMOVE THE PELLETS FROM THE BURNER AND
CONTACT AN AUTHORISED MCZ TECHNICIAN.
OPERATING MODE
4.7.
STAR-EGO stoves have two operating modes: MANUAL and
AUTOMATIC.
4.7.1. Manual and automatic
The stove can operate in one of these two different operating modes.
MANUAL mode allows only adjustment of the flame from out-put
power 1 to power 5, ignoring any ambient temperature measurement.
This mode is indicated by the word MANU on the control panel.
AUTOMATIC mode lets you set the desired temperature in the room
where the stove is installed. The stove will control its power
Operation
PELLET STOVES
INSTALLATION AND USE MANUAL
ALARM
CONDITION
FROM
THE
Technical service - Rights reserved MCZ Group S.p.A. - Reproduction prohibited
Chapter 4
39
page
B
A
B