INSTALLATION
2.2.
IMPORTANT!
Installation and assembly of the stove must be
carried out by qualified personnel.
The stove must be installed in an area with adequate space to allow the
stove to be cleaned and maintained.
The stove must be positioned in such a way that the plug is accessible.
The site must be:
Provided with enough make up air for proper operation of the
stove.
Have a properly grounded 110V outlet within 6'
Installation and repair of the Ego/Star Pellet Stove should be done by a
qualified service person. The appliance should be inspected by a
qualified service person before use and at least annually. Every 2000
hours of effective work a temporary service warning appears in display
at each ignition, to remind the requirement of a periodical inspection. It
is imperative that control compartments, burners, and circulating air
passageways of the Ego/Star be kept clean.
OPERATING AREA
2.3.
For proper operation and a good heat distribution, the stove must have
adequate make up air. This can be supplied by connecting the outside
air supply or by assuring that there is adequate ventilation in the home.
In bedroom or bathroom installations the outside air
connection is required!
Locating the stove in a room with an explosive
atmosphere is prohibited.
If the walls are not flammable, position the stove with a clearance to
the rear of at least 2,5".
For flammable walls, keep a minimum distance of 5" at the rear, 4" on
the sides and 40" at the front.
If the room contains objects which are believed to be particularly
delicate, such as drapes, sofas and other furniture, their distance from
the stove should be considerably increased. See page 16 for details.
If the flooring is made of wood, provide a floor
protection surface in compliance with current
national standards.
CONNECTION TO THE EXTERNAL AIR INTAKE
2.4.
It is essential that at least as much air must be able to flow into the
room where the stove is installed as is required for proper combustion
in the appliance and for the ventilation of the room. This can be
accomplished by connecting the outside air feature on the stove or by
providing a ventilated wall pass through 15 sq in min.
The air intake must:
Theoretical notions for installation
PELLET STOVES
INSTALLATION AND USE MANUAL
Technical service - Rights reserved MCZ Group S.p.A. - Reproduction prohibited
Chapter 2
10
page
4
15.5 In²
Example of pellet stove installation
3"
40"
Example of pellet stove installation
3"

Publicité