On the terminal indicated by the arrow, on the housings (A) and (B)
insert the two wires of the room thermostat. These wires must pass
through the hole G on the back of the stove. Thermostat and related
electrical cables are the user's responsibility. Installation by a
specialized technician is advised.
Once the thermostat is connected, the temperature detected by the
probe will continue to appear on the control panel of the stove however
only the temperature set on the thermostat will be used to control the
out-put.
The activation of the thermostat (on/off) on the control panel is
possible from the menu, settings, on/off option thermostat, as
explained in the diagram below.
70°F
OFF
Esc
<
Setting
Esc
<
Thermostat
4.7.4. Automatic mode with AUTO-ECO
This mode changes stove operation in automatic mode. Upon
reaching the temperature set by the user, the stove goes to power level
1 for a short period of time. At that point if the temperature remains
constant and above the set temperature the stove will shut down. The
stove comes back on automatically only when the room requires heat
again, but not before a period of time has passed for the stove to cool
off. This option is advisable only if the stove works in highly insulated
rooms or where there is low heat dispersion over time.
Operation
INSTALLATION AND USE MANUAL
21.04
Set
>
Set
>
PELLET STOVES
Mode:AUTO
Temp:72°F
Esc
<
Setting
Esc
<
Thermostat
Technical service - Rights reserved MCZ Group S.p.A. - Reproduction prohibited
Menu
Fan:A
Set
>
ON
OK
>
Chapter 4
42