MESSAGE ON
DISPLAY
A01
Fire fails to ignite
A02
Fire goes out abnormally
Pellet hopper temperature exceeds foreseen
A03
safety limit.
Overheating of the stove body
A04
The temperature of the exhaust has exceeded
pre-set safety limits
During
obstruction in the flue pipe occured or
A05
atmospheric agents disturbed the stove smoke
outlet (wind, snow, etc.), or door is simply
opend.
A06
The combustion blower is not able to provide
the primary air required for combustion.
Combustion Blower Failure
A08
The smoke probe is defective and does not
A09
properly measure the temperature of the
discharge smoke
A10
The plug is defective
Defective feed motor
A11
Defective electronic board
A13
A14
Generic failure of sensor
Operation
PELLET STOVES
INSTALLATION AND USE MANUAL
TYPE OF PROBLEM
the
function
of
the
Check the level of pellets in the hopper.
Check that the burn grate is properly inserted in its
housing and is clear of carbon build up.
Check whether there is power at the outlet.
It generally derives from a shutdown due to lack of fuel
(hopper empty).
The structure is too hot because the product has been
operating for too long at maximum power, or it is
poorly ventilated, or the distribution fans are faulty.
When the stove is sufficiently cold, press button B of
the control panel or OFF on the remote control to
cancel the alarm A03. Once the alarm is cancelled it is
possible to relight the stove normally.
The stove will shut off automatically. Let the stove cool
off for a few minutes, then re-light it.
Control the exhaust of the smoke the type of pellet
being used.
stove,
an
Control the correct closure of the door and eventual air
infiltrations (e.g. combustion blower inspection plug
missing). If all this checks are normal, protect the outlet
from the wind or control and eventually clean the
WHOLE flue system.
Draught difficulties or clogging of grate.
Check whether the grate is clogged by carbon and
clean as required.
If necessary clean the WHOLE vent system and the air
intake.
Check that the combustion blower housing is clean and
if it is dirt that is blocking it.
If not it is likely that the combustion blower is
defective. Call an authorized service centre to make the
replacement.
Contact an authorized service centre to replace the
component.
Contact an authorized service centre to replace the
component.
Contact an authorized service centre to replace the
component.
Contact an authorized service centre to replace the
component.
This alarm is not blocking, only a warning screen
appears. Contact an authorized service centre to
replace the component.