Water Connection - Angelo Po COMBIFIT CF623E Manuel D'installation, D'utilisation Et De Maintenance

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 100
The oven should be levelled: to ad-
just the height of the leveling feet
proceed as shown in fig. 2, using a
spirit level.
Unevenness or inclinations of a
certain degree can compromise the
operation of the oven.
Remove the entire protective film
from the external panels of the ap-
pliance, detaching it slowly to re-
move all traces of adhesive.
Make sure that all openings and
holes designed for heat intake/dis-
charge are not obstructed.
1.3. Water connection
G 3/4"
fig. 3
COMBIFIT
installation, use and maintenance manual
The water pressure must be of
maximum (600 kPa) 6 bars. If the
pressure of mains water is greater
than this value, it is necessary to
install a pressure reducer upstream
of the oven.
The minimum water pressure for
the proper operation of the oven
must be above 3 bar (only ovens
with self-cleaning).
The oven has an inlet for softened
water on the rear bottom side of the
oven. It will be on the left side for
ovens with 6 trays (fig. 3) and to the
right for ovens with 10 trays (fig.
4 pag.8). We always recommend
installing a water softener-descaler
to bring the hardness of the water
entering the appliance to values
between 6 ° and 12 ° F (60-120
ppm). (Requirements for supplied
water pag.45).
fig. 2
7

Publicité

Table des Matières
loading

Table des Matières