Quick Installation - Burkert 8041 Manuel Utilisateur

Masquer les pouces Voir aussi pour 8041:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

QuickInstallation
The current I or the frequency f are proportional to the flow rate Q (l/s),
the proportionality factor is called the "K factor":
I =K
with K1 and K2 in imp/l
The following formulae are used to calculate the K1 and K2 factors
needed to convert the current or frequency into a flow rate:
Full scale
K
Factor
1
= 100
K
10 m/s
1
K
fitting
= 200
K
5 m/s
1
K
fitting
= 500
K
2 m/s
1
K
fitting
with K
= K factor of the S020 fitting used
fitting
Example :
If the full scale of the transmitter is set to 5 m/s, the value of the
current output will be:
I = 40 Q + 4
3xK
fitting
with I in mA, K
in imp/l and Q in l/s.
fitting
Type 8041
f = K
xQ
1
xQ + 4
2
K
Factor
2
= 20
K
2
3xK
fitting
= 40
K
2
3xK
fitting
= 100
K
2
3xK
fitting
7.

QuicK insTAllATion

Unpack the device.
Order code
OK?
Yes
Unscrew the 4 screws and
remove the cover.
Select the frequency of the
main supply, using switch 1, see
§ 10.4.
Select the filter level using
switches 2 and 3, see § 10.5.
Select the current output
type, see § 8.3.1.
English
No
Contact the Bürkert
retailer
13

Publicité

Table des Matières
loading

Table des Matières