Install the device in the pipe in such a way that the distances
upstream and downstream are respected, depending on the
design of the pipes, see the EN ISO 5167-1 standard and Fig.
7 :
50 x DN 5 x DN
With regulating valve
25 x DN 5 x DN
Pipe with 2 elbows at 90°
18 x DN 5 x DN
With pipe extension
Fig. 7 : Distances upstream and downstream depending on the
design of the pipes
18
40 x DN 5 x DN
Pipe with 2 elbows at 90° in
3 dimensions
20 x DN 5 x DN
Pipe with 1 elbow at 90° or
1 T-piece
15 x DN 5 x DN
With pipe reduction
English
Type 8041
Installationandwiring
Respect the following additional mounting conditions to ensure
that the measuring device operates correctly:
-
it is preferable to install the sensor at an angle of 45° to a
horizontal centred on the pipe to prevent deposits on the elec-
trodes and measurement errors due to any air bubbles (see
Fig. 8 ) ;
Fig. 8 :
Mounting angle of the transmitter in the pipe
-
Ensure that the pipe is always filled up to the transmitter (see
Fig. 9 ) ;
-
ensure that the fluid flow direction is ascending in vertical
mounting (see Fig. 9 ) ;
-
prevent the formation of air bubbles in the pipe in the section
around the sensor (see Fig. 10 ) ;
-
the transmitter must be placed upstream of the injection point
of a liquid with high conductivity (e.g.: acid, basic, saline solu-
tion).
45°
45°