VENT CLEANING
To carry out this operation, proceed as follows.
Importante
This cleaning operation must only be carried out
by authorized and qualifi ed personel.
1) Run the steam oven at 100°C for half an hour.
2) Switch off the oven and disconnect the power
supply switch.
3) Spray cleaning solution from the end of the vent
hose (A) and let it sit for at least 15 minutes.
4) Rinse the hose by spraying water into it from the
end that opens onto the oven ceiling (do this with
the side of the oven closed).
5) Extract the container rack (B) from the oven and
clean it thoroughly.
6) Undo the screws to open the defl ector panel (C).
7) Loosen the screws (D) to remove the protection
(E).
8) Spray the detergent inside the vent hose (A) and
leave for at least 15 minutes.
9) Thoroughly clean the pipe (A) using a cleaning
GB
brush (not supplied).
10) Rinse the hose by spraying water into it from
the end that opens onto the oven ceiling and
from the inside (do this with the side of the oven
closed).
Importante
Seal the screws with silicone (D) before reinstal-
ling the protection (E).
11) Replace all when the operation is complete.
TROUBLESHOOTING
See paragraph "Troubleshooting" of the user instructions manual.
TABLE OF ALARM INDICATIONS
See paragraph "Table of alarm indications" of the user instructions manual.
3326460_GB_inst_rev.2
B
FAULT
- 4 -
A
Warning
E
A
D
C
ENGLISH