english
Sound pressure level
Motor
Speed
on rating plate
[kW]
[
1
/min]
0,75
2800 – 3000
3400 – 3600
1,1
2800 – 3000
3400 – 3600
1,5
2800 – 3000
3400 – 3600
2,2
2800 – 3000
3400 – 3600
3,0
2800 – 3000
3400 – 3600
4,0
2800 – 3000
3400 – 3600
5,5
2800 – 3000
3400 – 3600
7,5
2800 – 3000
3400 – 3600
11
2800 – 3000
15
2800 – 3000
18,5
2800 – 3000
22
2800 – 3000
14. Re-lubrication of motor bearings
The motor bearings are pre-lubricated on delivery.
Sound pressure
After approx. 3000 operating hours, the bearings must
level
be re-lubricated.
(~3000
/min)
1
[dB(A)]
60
65
60
65
When lubricating for the first time, use twice the amount
of lubricating grease as the lubricating channel is still
empty.
65
70
65
Frame size
70
65
to 11 kW
70
to 15 kW
70
The recommended grease type is Asonic GHY 72,
75
which is a polycarbamide-based lubricating grease.
75
80
15. Disposal
This product and its parts must be disposed of in accor-
65
dance with environmental protection regulations.
69
1. The local public or private disposal companies should
2. If there is no organization of this kind or it is refused
69
70
70
73
Before re-lubrication, the bottom plug
Note
in the motor flange and the plug in the
bearing cover must be removed to ensure
that old and excess grease can run out.
Quantity
of lubricating grease
[ml]
Drive end
(DE)
23
23
be consulted in this regard.
to accept the materials used in the product, the
product or any environmentally hazardous materials
can be taken to the nearest Biral company or work-
shop.
This product contains the following
Caution:
parts/materials for which special care
is required: electronic components
with PCB (in capacitors).
Non-drive
Lubricating
end
intervals
(NDE)
[hours]
20
3000
23
3000
55