Accessories

Sound muffler for installation in the cold air duct for additional
noise reduction within the living compartment
(part no. 40040-60100).
Fig. 8
Air outlet channel for additional noise reduction outside the
living compartment. Installed beneath the vehicle
(part. no. 40040-32500).
Fig. 9
The flexible air conditioning intake allows the air conditioning
system to be installed in a space that is sealed off from the
interior (e.g. false floor or rear storage space) and prevents
contaminated air from being drawn in (e.g. petrol fumes from
the rear storage space)
(part no. 40090-59100).
Fig. 10

Technical data

Determined on the basis of EN 14511 or Truma test conditions
Designation
Saphir comfort IR, comfort air conditioning system
Number of structural units
1
Dimensions L x W x H
710 x 400 x 290 mm
Weight
approx. 22.5 kg
Power supply
230 V – 240 V ~, 50 Hz
Maximum cooling power
2.4 kW
Effective power consumption
0.98 kW
Starting current
20 A (150 ms)
Power consumption
4.2 A
Protection class:
IP X5
Energy Efficiency Rate (EER)
2.4
Volume flow (cold air)
max. 380 m³/h
Refrigerant
R 407C / 0.45 kg
Contains fluorinated greenhouse gases covered by the Kyoto
Protocol. Hermetically sealed.
Global warming potential (GWP)
1774
CO2 equivalent
798.3 kg
Compressor oil
Diamond MA32, 300 cm³
Noise
depending on installation situation
Maximum incline of vehicle during operation
5° / 8 %
Usage limits
+16 °C to +43 °C.
– An interior air sensor prevents the compressor from operat-
ing at temperatures of less than +16 °C.
– An anti-freeze sensor prevents non-permitted ice formation
on the evaporator coil.
– A temperature switch prevents excessive current and tem-
perature at the compressor.
Right reserved to make technical changes!

Function diagram

Supply air
intake from
Compressor
the outside
Condenser
Fan
Supply air
Throttle
outlet to the
outside-downwards
High-pressure side
Fig. 11

Installation dimensions

The dimensions are in mm.
710
370
66
580
Fig. 12
Cold air
outlet
Circulated
air intake
from inside
Low-pressure side
95
95
95
104
17