Saphir comfort IR air conditioning system
Table of contents

Symbols used ...................................................................... 13

Safety instructions ........................................................... 13
Notes on using air conditioning systems ..................... 13
Remote control .................................................................... 14
IR receiver and manual on / off ........................................... 15
IR receiver / function indicator ............................................ 15
Start-up ................................................................................ 15
Switching on ....................................................................... 15
Temperature ........................................................................ 15
Mode ................................................................................... 15
Fan ....................................................................................... 15
Switching off ....................................................................... 15
Time ..................................................................................... 15
Timer ON / OFF .................................................................... 15
Reset .................................................................................... 15
Resend ................................................................................. 15
Setup ................................................................................... 16
Maintenance ..................................................................... 16
Troubleshooting ................................................................... 16
Remote control battery change ........................................... 16
Disposal ............................................................................. 16
Accessories ....................................................................... 17
Technical data ................................................................... 17
Installation dimensions ....................................................... 17
Declaration of conformity ............................................... 18
Intended use ........................................................................ 20
Approval .............................................................................. 20
Regulations .......................................................................... 20
Selecting a location ......................................................... 20
space is available ............................................................. 20
restricted ............................................................................ 21
Cold air distribution ............................................................. 21
Circulated air return ............................................................. 21
Installing the infrared receiver ............................................. 22
230 V electrical connection ............................................ 22
Function test / IR remote control mounting ........................ 22
Symbols used
The unit must only be installed and repaired by an
expert.
Symbol indicates a possible hazard.
Note containing information and tips.

Safety instructions

Repairs may only be carried out by an expert!
To avoid transportation damage, the device may only dis-
patched if the Truma Service Centre has been consulted
beforehand.
The power supply must be disconnected from the mains
(all poles) before opening the housing.
The 230 V, 3.15 A (slow, IEC 127) fuse in the unit can be found
on the electronic control unit and must always be replaced
with an identical fuse.
The device fuses and connection cables must only be replaced
by experts.
Guarantee claims, warranty claims and acceptance of liability
will be ruled out in the event of the following:
- Modifications to the device (including accessories)
- Failure to use original Truma parts as replacement parts and
accessories
- Failure to follow the installation and operating instructions
This may also invalidate the device operating permit, which in
many countries also denotes cancellation of the vehicle oper-
ating permit.
The refrigerant circuit contains R 407C refrigerant and must
only be opened in the factory.
The cold air outlet and and the circulated air intake must not
be obstructed under any circumstances. This is essential in
order to ensure that your device operates correctly.
The openings beneath the floor of the vehicle must be kept
free of dirt and slush. These openings must not be within the
range of the wheel spray - fit splash guard if necessary.
If underbody protection is being applied to the floor of the
vehicle, all openings beneath the vehicle must be covered so
that the spray mist that is created does not penetrate the de-
vice and cause malfunctions. Remove covers again when the
work is complete.
In order to avoid damage to the compressor, no uphill or
downhill slopes with an incline of more than 8 % must be
driven on when the device is being operated while driving
(e.g. with generator or voltage converter).
Do not operate the device in cooling mode for long periods
with the vehicle at an angle, since the condensation that is
produced may not be able to run away and may penetrate the
vehicle under unfavourable circumstances.
Notes on using air conditioning systems
- The Saphir comfort IR air conditioning system is designed for
minimal power consumption. You should still check whether
the camp site has adequate fuse protection (min. 4.2 A) be-
fore starting the equipment up.
- Park the vehicle in the shade if possible.
- Darkening with shutters and / or a canopy reduces the
amount of heat radiation.
- Clean your roof at regular intervals (dirty roofs heat up more
than clean roofs).
- The vehicle must be properly ventilated before starting the
equipment in order to remove accumulated warm air from
the vehicle.
- When aprons or the like are being fitted, please ensure that
adequate openings are present for dissipating the supply
air. The opening for the warm outgoing air should not be at
the inlet side.
- In order to obtain a healthy room climate, the difference
between the inside and outside temperatures should not be
too great. The recirculated air is cleaned and dried during
operation. A pleasant room climate is produced by drying
the moist air, even if the temperature difference is minimal.
- Keep all doors and windows closed when in cooling mode.
13