Accessories

Filter set, 2 pieces (part no. 40091-16800).
Fig. 5
Truma CP plus
Truma CP plus digital control panel with automatic air con-
ditioning system for the iNet-capable Truma heaters
Combi and Truma air conditioning systems Aventa eco,
Aventa comfort (from serial number 24084022 – 04/2013),
Saphir comfort RC and Saphir compact (from serial number
23091001 – 04/2012)
– The automatic air conditioning system function automatical-
ly controls the heater and the air conditioning system until
the required temperature is reached in the vehicle.
– With the Truma iNet Box extension, all TIN-Bus-capable
Truma appliances can also be controlled via the Truma App.
Figure 6
Truma iNet Box
The Truma iNet Box for simple networking and control of
Truma appliances with a smartphone or tablet computer using
the app.
– Simple installation and start-up via the Truma App
– Can be extended with the update function, which ensures
that it is always up to date
Figure 7
All manuals and user guides at all-guides.com

Troubleshooting

If these actions do not remedy the problem, please con-
tact Truma Service.
Fault
Cause / Remedy
Device not cooling
– Thawing procedure in progress
– Remote control temperature
setting reached or too high
Device not heating
– Defrosting process running
(outside temperature between
4 °C and 7 °C
– Outside temperature below 4 °C
Device cooling /
– Filter soiled, change filter
heating inadequately
or not at all
– External air routes soiled /
blocked
Moisture on underside
– Close windows and doors and
of air distributor
select high fan level
Water dripping out of
– Condensation trap on external
air distributor
unit blocked
– Seal between device and roof
not intact
– System at too much of an angle
Remote control
– Check batteries in remote con-
not working
trol and replace if necessary
Device not reacting
– Check whether there are ob-
to remote control
structions between the remote
commands
control and the IR receiver
– Is the remote control tuned to
the IR receiver? / tune remote
control to IR receiver.