Maintenance
Located on the front side of the unit is a fluff filter (n) and a
particle filter (p) for cleaning the air in the room.
The fluff filter (n) must be cleaned at regular intervals, at least
twice a year, and replaced if necessary (part no. 40090-58200).
We recommend that the particle filter (p) be replaced annually
at the start of the season (part no. 40090-58100).
In order to change the filters, pull fluff filter (n) forward at re-
cesses at top edge and remove from above. Remove particle
filter towards the front.
Ensure the installation position is correct! The arrows
imprinted on the unit must point towards the inside of
the device, and symbolise the direction of flow of the circulat-
ing air. The device must never be operated without the
filter. Without a filter the evaporator will become dirty, which
in turn will impair the performance of the device!
The condensation water drain is located beneath the floor of
the vehicle (page C, fig. C, 11). In order to allow the conden-
sation to drain away freely, check whether the drain is free
of dirt, leaves and the like at regular intervals. If this is not
done, there is a risk of condensation water penetrating
into the vehicle!
Trouble-shooting
Before calling Customer Service, please check the following:
–
Is the 230 V mobile home supply properly connected, and
are the fuses and protective switch in good order?
–
Is the temperature which has been set on the remote con-
trol less than the interior temperature?
–
Are the fluff filter (n) and the particle filter (p) on the front of
the unit or the air intake to the stowage box (in which the
device is installed) soiled or free?
–
Is the air supply opening in the floor of the vehicle free of
dirt, leaves and the like?
If this does not solve the problem, please contact the Truma
Service.
p
n
Changing the battery in the remote control
Please be sure to use leak-proof micro-batteries only, type
LR 3, AM4, AAA, MN 2400 (1.5 V).
The battery compartment is located on the rear of the
remote control unit.
When fitting new batteries, ensure
the polarity (positive / negative) is
correct!
Dead and used batteries may
leak and damage the remote
control unit. Remove the batteries if
the remote control is not going to be
used for an extended period.
No claims under guarantee will be considered for dam-
age caused by leaking batteries.
Disposal
Before disposing of a faulty remote control, always remove
the batteries and dispose of correctly.
The device must be disposed of in line with the administra-
tive regulations of the respective country in which it is used.
National regulations and laws (in Germany, for example, the
End-of-life Vehicle Regulation) must be observed.
Accessories
Noise suppressor for installation
in the cold air pipe for additional
noise reduction within the living
compartment
(part no. 40040-60100).
Blow-out channel for additional
noise reduction outside the
living compartment. Installed
beneath the vehicle
(part no. 40040-32500).
The flexible air conditioning in-
take allows the air conditioning
unit to be installed in a space
that is sealed off from the interi-
or (e.g. false floor or rear storage
space) and prevents contami-
nated air from being drawn in
(e.g. petrol fumes from the rear
storage space)
part no. 40040-59100.
OPEN
OPEN
11