Maintenance
Located on the front side of the unit is a fluff filter (n) and a
particle filter (p) for cleaning the air in the room.
p
n
The fluff filter (n) must be cleaned at regular intervals, at least
twice a year, and replaced if necessary (Part no. 40090-64600).
We recommend that the particle filter (p) be replaced annually
at the start of the season (Part no. 40090-58100).
To change the filters, disconnect cold air ducts beforehand.
Pull fluff filter (n) forward slightly at recesses at upper edge
and remove from above. Then withdraw particle filter (p) from
the front.
The arrows printed on the particle filter (p) must point to-
wards the unit when the filter is installed – these indicate
the recirculated air flow direction. The device must never be
operated without the filter. Without a filter the evaporator
will become dirty, which in turn will impair the performance of
the device!
The condensation water drain is located beneath the floor of
the vehicle. In order to allow the condensation to drain away
freely, check whether the drain is free of dirt, leaves and the
like at regular intervals. If this is not done, there is a risk of
condensation water penetrating into the vehicle!
Trouble-shooting
Before calling Customer Service, please check the following:
1. Is the motor home/caravan 230 V power supply lead con-
nected, and are the fuses and circuit breakers OK?
2. Is the temperature which has been set on the remote control
less than the interior temperature?
3. Are the fluff filter (n) and the particle filter (p) on the front of
the unit or the air intake to the stowage box (in which the unit
is installed) free?
4. Is the air supply opening in the floor of the vehicle free of
dirt, leaves and the like?
If these actions do not remedy the problem, please contact
Truma Service.
IR remote handset battery change
Please be sure to use leak-proof micro-batteries only, type
LR 3, AM4, AAA, MN 2400 (1.5 V).
The battery compartment is located on the rear of the remote
control unit.
OPEN
OPEN
No claims under guarantee will be considered for damage
caused by leaking batteries.
Before throwing away a defective remote control, it is essential
that the batteries be removed and disposed of in the proper
manner.
Accessories
When fitting new batteries, en-
sure the polarity (positive/ nega-
tive) is correct!
Dead and used batteries
may leak and damage the
remote control unit. Remove the
batteries if the remote control is
not going to be used for an
extended period.
Noise suppressor for installation
in the cold air pipe for additional
noise reduction within the living
compartment (Part no.
40040-60100).
Blow-out channel for additional
noise reduction outside the living
compartment. Installed beneath
the vehicle (Part no.
40040-32500).
The flexible air conditioning intake
allows the air conditioning unit to
be installed in a space that is
sealed off from the interior (e.g.
false floor or rear storage space)
and prevents contaminated air
from being drawn in (Part no.
40040-59100).
TG 1000 sinus power inverter for
operating the Saphir compact
with 230 V~ from the 12 V battery
supply (Part no. 40090-81000).
The wiring looms that are required
for operation with the air condi-
tioning unit must also be ordered.
13