Accessories
Filter set, 2 pieces (part no. 40091-16800).
Fig. 5
Troubleshooting
Fault
Cause / Remedy
Device not cooling
– Thawing procedure in progress
– Remote control temperature
Device not heating
– Defrosting process running
– Outside temperature below 4 °C
Device cooling /
– Filter soiled, change filter
heating inadequately
or not at all
– External air routes soiled /
Moisture on underside
– Close windows and doors and
of air distributor
Water dripping out of
– Condensation trap on external
air distributor
– Seal between device and roof
– System at too much of an angle
Remote control
– Check batteries in remote con-
not working
Device not reacting
– Check whether there are ob-
to remote control
commands
– Is the remote control tuned to
If these actions do not remedy the problem, please con-
tact Truma Service.
18
setting reached or too high
(outside temperature between
4 °C and 7 °C
blocked
select high fan level
unit blocked
not intact
trol and replace if necessary
structions between the remote
control and the IR receiver
the IR receiver? / tune remote
control to IR receiver.
Technical data
Determined on the basis of EN 14511 or Truma test conditions.
Power supply
230 V – 240 V ~, 50 Hz
Power consumption
Cooling: 4.2 A
Heating: 3.7 A
Starting current
28 A (150 ms)
Cooling power
2.4 kW
Heating power
1.7 kW (heat pump)
Air volume flow
max. 400 m³/hr.
Usage limits
+4 °C to 40 °C.
Maximum angle during operation
8 %
Weight
33 kg plus installation materials
Dimensions (W x H x D)
External: 660 x 248 x 1008 mm
Internal: 523 x 46 x 670 mm
Refrigerant
R 407C
Refrigerant content
see type plate on unit
Right reserved to make technical changes!
Installation dimensions
1008
Fig. 6
195
(215)
530
Fig. 7
(in mm)
670
400
(380)