Télécharger Imprimer la page

Ir Remote Control Battery Change; Disposal; Accessories; Technical Data - Truma Saphir comfort RC Instructions De Montage

Masquer les pouces Voir aussi pour Saphir comfort RC:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23

IR remote control battery change

Only use micro-batteries that will not leak, type LR 3, AM4,
AAA, MN 2400 (1.5 V).
The battery compartment is on the rear of the remote control.
When inserting new batteries, make sure the positive / nega-
tive terminals are connected correctly!
Fig. 7
Empty, used batteries can leak and damage the remote
control! Remove the batteries if the remote control is
not being used for a long period of time.
The tuning between the remote control and the air con-
ditioning system is retained if the batteries are removed.
No warranty given for damage caused by leaking
batteries.

Disposal

Before disposing of a defective remote control, always re-
move the batteries and dispose of them correctly.
The device must be disposed of in accordance with the ad-
ministrative regulations of the respective country in which it is
used. National regulations and laws (in Germany, for example,
the End-of-life Vehicle Regulation) must be observed.

Accessories

Sound muffler for installation in the cold air duct for additional
noise reduction within the living compartment.
(Part no. 40040-60100).
Fig. 8
The flexible air conditioning intake allows the air conditioning
system to be installed in a space that is sealed off from the
interior (e.g. false floor or rear storage space) and prevents
contaminated air from being drawn in.
(Part no. 40090-59100).
Fig. 9
18

Technical data

Determined on the basis of EN 14511 or Truma test conditions
Designation
Saphir comfort RC, comfort air conditioning system
Number of structural units
1
Dimensions L x W x H
628 x 400 x 290 mm
Weight
approx. 23.5 kg
Power supply
230 V – 240 V ~, 50 Hz
Maximum cooling power
2.4 kW
Heating power
1.7 kW
Effective power consumption
0.98 kW
Starting current
20 A (150 ms)
Power consumption
4.2 A
Protection class:
IP X5
Energy Efficiency Rate (EER)
2.4
Volume flow (cold air)
max. 380 m³/h
Refrigerant
R 407C / 0.45 kg
Contains fluorinated greenhouse gases covered by the Kyoto
Protocol. Hermetically sealed.
Global warming potential (GWP)
1774
CO2 equivalent
798.3 kg
Compressor oil
Diamond MA32, 300 cm³
Noise
depending on installation situation
Maximum incline of vehicle during
operation
5° / 8 %
Usage limits
+4 °C to +43 °C.
– An interior air sensor prevents the compressor from operat-
ing at temperatures of less than +16 °C during cooling.
– An anti-freeze sensor prevents non-permitted ice formation
on the evaporator coil.
– A temperature switch prevents excessive current and tem-
perature at the compressor.
Right reserved to make technical changes!

Function diagram

Supply air
intake from
Compressor
the outside
Evaporator /
condenser
Fan
Supply air outlet
to the outside-
Throttle
downwards
Fig. 10
Cold air /
warm air outlet
Fan
Condenser /
evaporator
Filter
Circulated air intake
from inside

Hide quick links:

Publicité

loading