4.3.3. Dosing proportional to a pulse duration («EXT.[T]» Option)
This option enables the initiation of a dosing volume proportional to the time during which
binary data input 1 is enabled. The following prompts are displayed within the principal
menu during the dosing operation.
Totalizer
display
Batch controller 8035
Fig. 7 Example of electrical connection
«ALARM» prompt during the dosing operation: dosing problem (see § 5.1.).
During the dosing of the selected volume, it is possible to display the flow rate, to pause, to
reset or to stop the operation. These facilities are only selected on the keypad. (see § 4.3.4.
and § 4.3.5)
4.3.4. Display of flow rate and the initial preset volume during the dosing
To display the flow rate and of the initial preset volume values during the dosing operation,
press the
key briefly. This is a useful facility irrespective of the dosing option chosen.
Countdown of the
dosing operation
Initial preset volume
in progress
221
L
250
2885 L
1
Activation time
proportional to dosing
volume
1 2 3 4 5 6 7 8 9 10 11
Supply
12..30Vdc
Flow rate
L
2.34 L/S
2 s.
2 s.
Automatic refresh after 2 s