Type 1094 EV
Operation and function
8.4.
adjustment and operation of the
controller
To adjust the controller in a gasoline pump, all components, signal
lines and the gas meter from the calibration case must be connected
correctly.
side selection
Each side of the gasoline pump can be controlled separately via the
slide switch (side selection).
The appropriate side of the gasoline pump is
controlled by pushing the switch up or down.
Fig. 11:
Selecting the side of the gasoline pump
suB-d plug
(connection to the manual control unit type Mkne-1094)
The controller is operated and calibrated exclusively via the external
manual control unit Type MKNE-1094 which is connected to the con-
troller via a 9-pole SUB-D plug.
Configuration of the SUB-D plug:
pin
1
2
Side 1
3
4
5
6
Side 2
7
8
9
Table 4:
i/O
description
nc
OUT
Clock for serial communication
BIDIR
Data line
nc
PWR
GND
nc
PWR
+5 V
nc
nc
Configuration of the SUB-D plug