Burkert 8035 Manuel D'utilisation page 46

Controleur de dosage
Masquer les pouces Voir aussi pour 8035:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2 SPECIFICATION
Medium
Pressure class
Max. medium temperature
Max. viscosity
Max. solid particle rate
Electrical features
Power supply
Current consumption
IN1 to IN4 inputs (volume selection)
OUT output, indication of the
batch status
Relay outputs
Wiring
Materials
Housing
Cover with lid
Front foil
Screws
Cable glands
BATCH CONTROLLER 8035
PN 10 or PN16, depending on fitting material, see
also temperature/pressure diagram, § 3.1
PVC: 50°C
PP, PVDF, stainless steel, brass: 100°C
300 cSt.
1%
12-30 VDC, filtered and regulated,
or 115/230 VAC, depending on version
70 mA, without consumption of inputs/output
4 binary inputs, 5-30 VDC, 3,3 k
Transistor NPN, open collector,
0 - 30 VDC, 100 mA, protected,
4 possible statuses (see § 4.1.4)
2 relays, 3 A, 230 VAC, adjustable
Through shielded cable, 1,5 mm
section, 50 m max. length
PC
PC
Polyester
Stainless steel
PA
E-7-
Ω
impedance