5.1.2.«[T] ERROR» prompt
This error prompt only occurs in the «EXT.[T]» option. It is displayed during a dosing ope-
ration if the duration of the pulse is greater than 300 seconds, or if it is greater than the
duration necessary to deliver the relevant volume.
It will also appear if the volume to deliver is greater than 100000 (l, m
delivered has reached 100000 (l, m
T [ERROR]
(**) When in mode EXT.MEM or EXT [T], you can also press the Enter key on the keypad.
5.1.3. «ERROR» prompt
The «ERROR» prompt flashes then the calibration parameter values have been lost. Press
the ENTER key, the Main Menu is displayed, but the unit is set in the basic default configu-
ration (see § 5.3). It is necessary to re-program the driver unit. If the display of this prompt
recurs, return the unit to your supplier.
5.2. Transducer maintenance
In correct installation conditions, the 8035 Batch controller is maintenance free. If clogging
occurs, the immersed parts of the sensor can be cleaned with water or any other cleaning
agent suitable for use with PVDF.
5.3 Factory and user settings
Language:
Unit flow:
Unit totalizers:
Unit batch:
K-Factor:
Batch option:
Quantities V1 to V7:
BATCH CONTROLLER 8035
3
, etc.) and when the pulse has not been switched off.
**
Device ready for a new batch
4
(see 4.3.3)
Overfill correction:
English
Alarm DURING: On,DEL1 = 100
L/s
L
Alarm AFTER: On, DEL2 = 100
L
Relay 1:
001.00
MEM+MANU
inversion:
00000
Relay 2:
inversion:
E-33-
3
, etc.) or if the volume
yes
DEL = 000
100 %
NO
VALVE
NO