K-Factor; Dosing Options - Burkert 8035 Manuel D'utilisation

Controleur de dosage
Masquer les pouces Voir aussi pour 8035:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4 CONFIGURATION

4.4.3 K-factor

The K-factor of the fitting is entered within this menu (see instruction manual fitting S030).
The "TEACH IN" function allows the practical determination of the specific K-factor. The
user only needs to run a known volume through his system.
Example: In order to determine a volume as accurately as possible, the user shall fill a tank
of 100 l. When the message "TEACH YES" appears, he presses the ENTER key to start the
measuring procedure. The message "FILL END" (end of filling) will appear. He then swit-
ches on a pump or opens a valve. As soon as the tank is empty, he switches off the pump
or closes the valve. Pressing Enter stops the measurement. The user will then be asked to
enter the volume (100 l). The calculated K-factor is displayed after confimation.
Note: The device uses the last K-factor entered or determined .
K-FACTOR
ENTER
OPTION
OPTION
Note: A decimal point can be entered by simultaneously pressing keys
always be positioned to the right of the flashing digit. Three positions are possible, «00000»,
«0000.0» or «000.00».
Adjustment range for the K factor : 0,01 to 99999.

4.4.4. Dosing Options

Selection the dosing option from:
LOC.MEM, LOC.MANU, MEM+MANU, EXT.MEM, and EXT.[T]. For more information on
these options, see § 4.2
BATCH CONTROLLER 8035
TEACH N
ENTER
ENTER
TEACH O
ENTER
Start of measurement.
ENTER
Indication of calculated
K-factor.
E-24-
K=000.00
Entering of K-factor as
specified in the charts.
0......9
K=046.60
END DOSE
ENTER
Stop of
measurement.
Entering the measured volume.
Same unit as for flow.
K=044.12
ENTER
0......9
0000.0 L
0......9
0200.0 L
. It will