5 MAINTENANCE
5.1 Fault prompts
5.1.1. «Alarm» prompt
"ALARM" PROMPT DURING A DOSAGE
The «ALARM « prompt will be displayed during a dosage operation (irrespective of the do-
sage option) if one or both valves are open but the controller does not detect any flow. The
time delay before triggering the alarm is set in the Calibration menu. (see § 4.4.6).
A dosage that has been stopped by the alarm can either be continued or cancelled:
a) Manual or automatic dosage activated by LOC.MANU, LOC.MEM or
MEM+MANU
ALARM
ENTER
(*) When in mode MEM+MANU, LOC.MEM or LOC.MANU, you can also start the dosage using the 'Start/Pause'
Binary Data Input.
b) Dosage through Binary Inputs and activated by EXT.MEM
ALARM
1
2
3
Place the Binary
Inputs to 0
(**) When in mode EXT.MEM or EXT [T], you can also press the Enter key on the keypad.
CONTINUE
RESET
**
RESET
then
4
E-31-
BATCH CONTROLLER 8035
Current batch
ENTER
continues
*
Device ready for a new batch
ENTER
(see 4.3.1 or 4.3.2)
*
Device ready for a new
**
batch (see 4.3.2)
4
OR
CONTINUE
1
2
3
Place the Binary Inputs
to the position of the
current dosage
**
4
Current batch
continues