Technical Data - Burkert 8035 Manuel D'utilisation

Controleur de dosage
Masquer les pouces Voir aussi pour 8035:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2 SPECIFICATION

2.4 Technical Data

Pipe diameter
Environment
Ambient and storage
temperature
Relative humidity
Protection rating
Flow rate measurement
Measuring range
Measuring error
Linearity
Repeatability
(*) Under reference conditions i.e. measuring fluid water, ambient and water temperatures of
20 °C, applying the minimum inlet and outlet pipe straights, matched pipe dimensions.
o.F.S = of Full Scale (10 m/s); o.R = of Reading
BATCH CONTROLLER 8035
DN6 to DN65
0 to 60 °C
max 80 %, non condensated
IP 65
0.3 to 10 m/s
1. With In-line calibration ("Teach-In"):
≤ ±
0.5% o.F.S (at 10 m/s) *
2. With standard K factor:
± (0.5% o.F.S + 2.5% o.R) *
Max. error [%]
F.S. = of the full scale
10
M.V. = of the measured value
8
6
4
2
1
2
3
4
-2
-4
Typical Burkert curve
-6
Standard calibration
-8
Calibration with Teach-In
-10
± 0.5% o.F.S (at 10 m/s) *
0.4% o.R *
E-6-
9
5
6
7
8
10
Flow velocity [m/s]

Publicité

Table des Matières
loading