3 INSTALLATION

3.1 Installation Guidelines

- The batch controller 8035 can only be used to measure pure, liquid and
water ressembling fluids (solids content
on-line calibration).
- The device is not suited for dosing gases.

Pressure-Temperature-Diagram

Mind pressure-temperature dependence according to the respective fitting materials.
Installation Guidelines
Determine the appropriate pipe diameter using the flow diagrams in annex.
For installing the fitting onto the pipe, respect the recommendations described in the corre-
sponding instruction manual.
The device must be protected from the rain, constant heat radiation and
other environmental influences such as magnetic fields or direct exposure
to sunlight.

3.2 Process mounting

1. The fitting "1" must be installed into the pipe
according to the installation specifications (see
§ 3.1 and fitting instruction manual).
2. Fasten the electronic housing "2" to the
fitting using the bayonet connection, and turn
by 30°.
3. Tighten the electronic housing with the
screw "3".
4. Wire according § 3.4.
P bar
Application range
16
15
14
13
12
PVC + PP
11
10
9
PVDF
8
7
6
5
4
PVC (PN10)
3
2
PP (PN10)
1
0
-50
-30
-10
+10
+30
+50
Fig. 2 Pressure-temperature diagram
E-8-
BATCH CONTROLLER 8035
1%, viscosity max. 300 cSt with
Metal (PN16)
PVDF (PN10)
T ∞C
+70
+90 +110 +130
3
2
1