B
Locking clamp
C
Pressure gauge
D Lifting point
E
Turntable holder arm
F
Turntable
G Bead breaker disc
H Hook tool
I
Tool rotation lever
P
R
L
Platform
M Tool holder arm release pedal
N Carriage
O Tool holder arm
- E
- Operator's manual HD 700
nglish
See fig.10.
P
Control lever
Q Turntable opening/closing control
R
Turntable rotation pedal
Start the machine with the main switch (A, Fig.
9) and make sure that the hydraulic power unit
motor is rotating in the direction indicated by
the arrow (A, Fig. 11) which can be seen on the
motor cap.
Otherwise, the rotation direction must be cor-
rected immediately in order not to damage the
pump unit.
All machine parts are powered by low voltage
(24V), with the exception of the hydraulic power
unit and the turntable rotation motor, which are
powered with mains voltage.
Make sure that all parts of the hydraulic cir-
cuit are tightened correctly. If pressurised oil
Q
escapes, it can cause serious injury.
The machine is equipped with devices that
guarantee the operator's safety:
1) Check valve on the turntable opening line
(located inside the swivel connector, see Fig.
10
A
12A).
Prevent the wheel from falling due to accidental
breakage of the oleodynamic circuit.
2) Dual seal, pilot-operated check valve (see
Fig.12B).
Prevent the turntable holder arm from falling
suddenly in the case of accidental breakage to
11
the oleodynamic circuit.
CAUTION
CAUTION
UK